Utility of dynamic preload indices of hypovolemia in isoflurane-anesthetized horses.
Byrne J, Guedes AG, Hickey C, Hatschbach E, Walters B, Rendahl A, Tearney C · Veterinary anaesthesia and analgesia · 19 February 2026
SPV% and PPV% are useful dynamic preload indices in anesthetized horses; PVI% is not reliable.
This prospective experimental study evaluated three dynamic preload indices—systolic pressure variation (SPV%), pulse pressure variation (PPV%), and plethysmographic variability index (PVI%)—for detecting hypovolemia in eight isoflurane-anesthetized horses. Animals underwent graded hemorrhage (5 mL/kg increments to 25 mL/kg) followed by autotransfusion while hemodynamic parameters and cardiac output were continuously monitored. Baseline values were SPV% 9%, PPV% 14%, and PVI% 12%. At maximal hemorrhage (25 mL/kg), optimal cut-off values were SPV% 16.1% (96% accuracy), PPV% 28.5% (90% accuracy), and PVI% 15.4% (72% accuracy). Inverse correlations with cardiac output were strongest for PPV% (-0.49, p<0.007) and SPV% (-0.34, p=0.131), while PVI% showed weak correlation (-0.20, p=0.253). Accuracy of all indices improved proportionally with blood volume loss. The authors conclude that SPV% and PPV%, but not PVI%, represent useful dynamic preload indices for detecting hypovolemia in anesthetized horses with negative correlation to cardiac output.
This summary was distilled by AI and may occasionally misinterpret data. Confirm critical details with the primary literature before clinical application.